![]() They enable the motor to meet limit value class C1 requirements in accordance with EN 61800-3 in EMC-compliant installations. ![]() HD series output chokes suppress interference emitted from unshielded motor cables. These line filters ensure that limit value class C1 is maintained on the supply end. They suppress interference emissions on the line side of inverters. NF type line filters are available for EMC-compliant installation as specified by EN 61800-3. This is an important characteristic in rough industrial power supply systems, especially if the inverter is installed near a supply transformer. ND series line chokes increase inverter overvoltage protection. Using an integrated temperature sensor, the resistor can be protected without external monitoring. Using the MDR60A/MDR61B lets you save power and installation costs.īW series braking resistors are available for operating MOVITRAC ® B frequency inverters and MOVIDRIVE ® B drive inverters as generators. In regenerative mode, the power is fed back into the supply system. The regenerative power supply can supply multiple units with power using a central power supply connection. MOVIDRIVE ® MDR60A 15 kW to160 kW MOVIDRIVE® MDR61B 160 kW to 315 kW regenerative power supply The MOVITOOLS ® MotionStudio program package lets you conveniently start up, set parameters and run diagnostics for MOVITRAC ® B frequency inverters and MOVIDRIVE ® B drive inverters. MOVITOOLS ® MotionStudio engineering software
0 Comments
Leave a Reply. |